Page 165 - Catalogue 2019
P. 165

9
                   QUAD-RING Seal
 Description
 9
 Original QUAD-RING Seals are four lipped seals with a
 specially developed sealing profile.
                                                                  9
                                              QUAD-RING Seals are self energizing double-acting
                                              sealing elements. The forces acting in radial or axial
 A wide range of elastomer materials for both standard
                                              direction due to the installation give QUAD-RING Seal its
 and special applications allows practically all liquid and  Method of Operation                                       9
 gaseous media to be sealed.                  initial leak-tightness (initial squeeze). These forces are
 BUTTERFLY VALVE Q 011                  BUTTERFLY VALVE Q 011
                                              superimposed by the system pressure.
 9
 QUAD-RING Seals are vulcanized as a continuous ring.
 They are characterized by their annular form with a four  An overall sealing force is created which increases with
 lipped profile. Their dimensions are specified with the
 TECHNICAL DATA  TORQUE                    DN increasing system pressure (Figure 2). Under pressure, the
                                                    Size
                                           80 seal behaves in a similar way to a fluid with high viscosity
             (Md) are based on dry media 1).
 inside diameter d and the cross-section W (Figure   3                               15
 Nominal diameter:  DN 80 - DN 400  - The torque values specifi ed   [mm]  [in]      Md
 1
                                                                                     20
                                                     4
 Face-to-face:  EBRO works standard    and are measured with air at   100  and the pressure is transmitted uniformly to all sides.
             a temperature of 20 °C
                                                     5
                                          125
                                                                                     25
 Flange accomodation:  EN 12220  - The values specifi ed are based  150  6            30
 EN 24154   on the initial breakaway torque  200     8                               35
            (disc disengages from seat,   250        10                              40
 Top fl ange:  EN ISO 5211  torque then drops)  280  11                              45
                                          300        12                              50
 Marking:  EN 19  Regarding the dimensioning of
           actuators, please contact our  350        14                              55
 Tightness check:  EN 12266 (Leakage rate A)  engineers.  400  16                    60
                W
 d1                                                                                                      All values in Nm
 Temperature range:  0°C to +50°C
 Operating pressure:  max. 1 bar
                           W


 High grade double block butterfl y valve, with test/lubrication port for
 laboratory, clean room and pharmaceutical applications.   9
 Figure 1  QUAD-RING Seal dimensioning
           DOUBLE FUNCTION
           Wafer  type  butterfl y  valve  in  eccentric  construction  with  a
 9
           „Double Block and Bleed“ sealing design.
 QUAD-RING Seals are supplied in dependence on the
           A  cavity  space  between  the  sealing  lips  is  pressurized  or  de-
 FEATURES  American O-Ring Standard AS 568 B.pressurized  thru  the  test  port.  An  air  test  gauge  is  connec-
           ted  to  the  port  and  displays  even  little  leakages  by  a  pres-
 - Can be installed in any desired position  sure  surge  or  drop.  The  volume  of  the  hollow  space  is  very
 - Multiple shaft bearings  small.  Therefore  it  is  possible  to  make  visible  lowest  leakages
 - Can be disassembled, material-specifi c recycling possible  Advantages  under pressure.
           The  exact  position  of  the  closed  valve  is  controlled  by  a  me-
                9
           chanical  stop.  Even  after  many
 In contrast to the O-Ring, QUAD-RING Seal has the Open/Close  cycles,  exact
           repeatability of the closed position will be observed.
 following advantages:

 GENERAL APPLICATIONS IN HVAC PLANTS:  - -- - Avoids twisting in the groove. Due to its special profile,
 - Pharmaceutical industry  the seal does not tend to roll in the groove during  The sealing  is similar to  a quadratic ring.  A large range of
                                                                 rubber compounds are available, which ensures the use in various
 - Clean room technology  reciprocating movement.                applications of ventilation technology.
 - Research laboratories                                         The low torque of the Q  011 requires minor actuator power and
 - Laboratories                                                  therefore guarantees an energy-effi cient automation of the valve.
 - -- - Low friction.
                                                           Pressure
 - -- - Very good sealing efficiency. Due to an improved
         9
 pressure profile over QUAD-RING Seal cross-section,
 a high sealing effect is achieved.
 The integrated coupling provides the port for the air test gauge and
 the lubrication press.
 - -- - A lubricant reservoir formed between the sealing lips
 improves start up.                                                www.ebro-armaturen.com


 Q 011 an O-Ring, the mould line flash lies in the trough,
 - -- - Unlike  4.10                                               post@ebro-armaturen.com
                                                                   01.2019
 between and away from the critical sealing lips.
                                                                                    9
                                              Figure 2          QUAD-RING Seal squeeze with and
                                                                without system pressure

























                                                                 Latest information available at www.tss.trelleborg.com